Fire Survival Cable

FP200 Cables Suppliers in UAE

Fire Survival Cable Specification

 

Verified Manufacturer

Verified Manufacturer (Contact directly for instant quote)

Fire Survival Cable Specification

Voltage Temprature Range Minimum Bending Radius
600 / 1000V  -40°C to + 90°C 12 x overall diameter of cable
Core Conductor Material Flame Categories
  • Multi-core (up to 400 mm2)
  •  Single-core (up to 630 mm2)
  • Copper
  • Aluminium
  • D
  • B
  • A
  • C
Standards Screening Test Report As Per BS 7846
  • BS 6387 (CAT B/A/C, W, Z)
  • BS 7846 (CAT F2/F1/F3, VDE-0815 & 0816)
  • ICE 331
  • BS 6387
  • IEC 60332
  • IEC-189 (1 & 2)
  • IEC 60331
  • BS-7955
  • Mesh braided
  • Al-Mylar
  • Resistance to Fire alone (Protocol C)
  • Resistance to Fire with Mechanical Shock (Protocol Z)
  • Resistance to Fire with Water (Protocol W)
Insulation Approval Features
  • XLPE
  • Low Smoke
  • Zero Halogen
  • BS 6387
  • LPCB
  • CE
  • BS 7846
  • Low smoke and toxic gas emissions
  • Flame retardant properties
  • Fire resistance
  • Ease and low cost of installation
  • Zero halogen gases
Construction Conductor Type Outer Sheath
  • Non-armoured
  • Armoured
  • Stranded (ABC/ATC) copper
  • high conductivity Solid
  • XHFR
  • HFFR

 

Fire-Proof Cables as per BS 6387/ BS 7629 / EN 50525-3-41

Standards and Testing of FP200 Cables

  • Fire Resistance test:BS 6387, IEC60331,
  • Flame spread test: BS EN 60332-3, IEC 60332-1
  • Flame Propagation Test: BS EN 60332-1, IEC 60332-1
  • Acid Gas emission test: BS EN 50267, IEC 60754
  • Resistant to Fire with water: BS 6387
  • Limiting Oxygen Index(LOI): ASTM D 2863, BS EN ISO 4589
  • Smoke emission test: BS EN 61034, IEC 61034
  • Determination of Acidity:BS EN 50267, IEC 50754

 

Resistance to fire alone
950 o C for 20 minutes (short duration) 750 o C for 3 hours 650 o C for 3 hours 950 o C for 3 hours
S B A C

 

Resistance to fire with water
W

 

Resistance to fire with mechanical shock
750 o C 650 o C 950 o C
Y X Z

 

Fire Resistant Cable for fire alarm, fire detection & emergency elevators or lighting

Fire-Proof Cables Application

  • Tunnels
  • Theatres
  • Hospitals
  • Shopping Developments
  • Oil & Petrochemical Plants
  • Mass Transit Railways
  • Computer Installations
  • Power Stations
  • Fire Pumps
  • Emergency Generators
  • Ventilating Fans
  • Emergency Lighting
  • Emergency Elevators
  • High Rise Buildings

 

2 hours Fire Rated Cables as per BS 8491 standard in Dubai

Fire Rated Cables Construction

Conductor For sizes up to and including 16mm² are offered in circular
Construction Plain annealed stranded copper conductors.
Bedding An extruded layer of LSZH compound.
Armour Single layer of galvanized steel wires.
Insulation Mica (fire – resistant) tapes
Sheath Thermoplastic low smoke zero halogen (LSZH) compound.

 

Low Smoke Zero Halogen High Fire Wire compliance with NFPA 130/ 502 , FT4-ST1, FT2 & IEEE 1202

Most Frequently Used Types Of Fire Guard Cable

Single Core Fire Resistant Cable

Single Core Fire Resistant Cable

XL-LSZH Insulated Cabless

XL-LSZH Insulated Cables

BS 6387 Sheath Cables

BS 6387 Sheath Cable

Fire Resistant Screened Cables

Fire Resistant Screened Cable

Flame Survival Cable

Flame Survival Cable

Fp200 Cables

Fp200 Cables

Flame Retardant Cables

Flame Retardant Cables

Fire Rated Armoured Cables

Fire Rated Armoured Cables

 

Technical Dimensions of BS 6387 Sheath Cable

Part Number Nominal Cross Sectional Area (Sq. mm) Nominal Armour Wire Diameter (mm) Insulation Thickness (mm) Approx. Cables Weight (kg/km) Approx. Diameter Under Armour (mm) Max. AC Conductor Resistant at 90°C (O/km) Approx. Overall Diameter (mm) Max. DC Conductor Resistant at 20°C (O/km) Reactance at 50Hz (O/km) Max. Arm. Resistant at 20°C (O/km) AC Impedance at 90°C (O/km)
3 Core 1.05* 0.09 0.06 423 9.00 15.0428 13.05 12.01 0.0104 10.02 15.0428
1.05* 0.09 0.06 423 9.00 15.0428 13.05 12.01 0.0104 10.02 15.0428
2.05* 0.09 0.07 544 10.05 9.0448 15.00 741 0.0101 8.02 9.0448
4* 0.09 0.07 644 11.05 5.0878 16.05 4.061 0.0099 7.05 5.0878
6* 0.09 0.07 738 13.00 3.0927 17.05 3.008 0.0094 6.06 3.0925
10″ 1.025 0.07 1085 15.00 2.0333 20.05 1.083 0.0093 4 2.0335
16 1.025 0.07 1313 17.00 1.0466 22.05 1.015 0.0088 3.06 1.0469
25 1.06 0.09 1803 20.00 0.0927 26.05 0.0727 0.0082 2.05 0.093
35 1.06 0.09 2202 22.00 0.0668 29.00 0.0524 0.0077 2.03 0.0673
50 1.06 1.00 2453 22.05 0.0494 29.05 0.0387 0.0076 2 0.05
70 1.06 1.01 3202 26.00 0.0342 33.00 0.0268 0.0075 1.08 0.0349
95 2.00 1.01 4455 30.00 0.0247 38.00 0.0193 0.0074 1.03 0.0258
120 2.00 1.02 5305 33.00 0.0196 41.05 0.0153 0.0072 1.02 0.0209
150 2.05 1.04 6705 37.00 0.016 46.05 0.0124 0.0073 0.078 0.0176
185 2.05 1.06 8052 41.00 0.0128 51.00 0.00991 0.0073 0.071 0.0148
240 2.05 1.07 9953 46.00 0.0099 56.00 0.00754 0.0072 0.063 0.0122
300 2.05 1.08 12053 51.00 0.008 61.00 0.00601 0.0072 0.058 0.0107
400 2.05 2.00 14803 57.00 0.0064 67.05 0.0047 0.0071 0.052 0.0096
2 Core 1.05* 0.09 0.06 415 8.05 15.0428 13.00 12.01 0.0104 10.07 15.0428
1.05* 0.09 0.06 415 8.05 15.0428 13.00 12.01 0.0104 10.07 15.0428
2.05* 0.09 0.07 495 10.00 9.0448 14.05 7.041 0.0101 8.08 9.0448
4* 0.09 0.07 575 11.00 5.0878 15.05 4.061 0.0099 7.09 5.0878
6* 0.09 0.07 658 12.05 3.0927 17.00 3.008 0.0094 7 3.0928
10* 0.09 0.07 828 14.00 2.0333 19.00 1.083 0.0093 6 2.0335
16 1.025 0.07 1005 16.00 1.0466 21.05 1.015 0.0088 3.08 1.0469
25 1.025 0.09 1105 15.05 0.0927 21.02 0.0727 0.0082 3.07 0.093
35 1.06 0.09 1555 17.05 0.0668 24.00 0.0524 0.0077 2.05 0.0673
50 1.06 1.00 1855 20.00 0.0494 26.05 0.0387 0.0076 2.03 0.05
70 1.06 1.01 2455 23.00 0.0342 30.00 0.0268 0.0075 2 0.0349
95 2.00 1.01 3345 26.00 0.0247 34.00 0.0193 0.0074 1.04 0.0258
120 2.00 1.02 3898 29.00 0.0196 37.00 0.0153 0.0072 1.03 0.0209
150 2.00 1.04 4645 32.00 0.016 40.00 0.0124 0.0073 1.02 0.0176
185 2.05 1.06 5945 36.00 0.0128 45.05 0.00991 0.0073 0.082 0.0148
240 2.05 1.07 7345 40.00 0.0099 50.00 0.00754 0.0072 0.073 0.0122
300 2.05 1.08 8695 44.00 0.008 54.05 0.00601 0.0072 0.067 0.0107
400 2.05 2.00 10745 49.05 0.0064 60.00 0.0047 0.0071 0.059 0.0096
4 Core 1.05* 0.09 0.06 423 9.00 15.0428 13.05 12.01 0.0104 10.02 15.0428
1.05* 0.09 0.06 522 10.00 15.0428 14.08 12.01 0.0104 9.05 15.0428
2.05* 0.09 0.07 618 11.05 9.0448 16.00 7.041 0.0101 7.07 9.0448
4* 0.09 0.07 725 13.00 5.0878 17.08 4.061 0.0099 6.08 5.0878
6* 1.025 0.07 985 14.05 3.0927 20.00 3.008 0.0094 4.03 3.0925
10* 1.025 0.07 1255 16.05 2.0333 22.00 1.083 0.0093 3.07 2.0335
16 1.025 0.07 1635 19.00 1.0466 24.05 1.015 0.0088 3.02 1.0469
25 1.06 0.09 2145 22.00 0.0927 28.05 0.0727 0.0082 2.03 0.093
35 1.06 0.09 2645 24.05 0.0668 31.05 0.0524 0.0077 2 0.0673
50 1.06 1.00 3103 26.00 0.0494 33.02 0.0387 0.0076 1.08 0.05
70 2.00 1.01 4405 30.05 0.0342 39.02 0.0268 0.0075 1.02 0.0349
95 2.00 1.01 5653 34.05 0.0247 43.02 0.0193 0.0074 1.01 0.0258
120 2.05 1.02 7252 38.05 0.0196 48.06 0.0153 0.0072 0.076 0.0209
150 2.05 1.04 8553 42.05 0.016 53.00 0.0124 0.0073 0.068 0.0176
185 2.05 1.06 10304 47.05 0.0128 58.00 0.00991 0.0073 0.061 0.0148
240 2.05 1.07 12895 53.05 0.0099 64.05 0.00754 0.0072 0.054 0.0122
300 2.05 1.08 15545 59.00 0.008 70.03 0.00601 0.0072 0.049 0.0107
400 3.015 2.00 20245 66.05 0.0064 79.08 0.0047 0.0071 0.035 0.0096

 

Fire Proof Cable Duration

Standard / Reference Fire Proof Cable Duration
BS8434-2 Fire rated 120mins fire impact and water at elevated temperature
EN 50200 Annex E Fire rated 30mins – Fire impact and water
BS8519 Cat 3 Fire rated 120mins
PH60 Fire rated
60 minutes
(1 hour)
PH30 Fire rated
30 minutes
F2 Fire rated as BS6387 CWZ
CR1 Cable rated 75mins circuit integrity
PH120 Fire rated
120 minutes
(2 hours)
E90 Cable rated 90mins as part of a holistic system
F60 Fire rated
60mins (1 hour) to BS8491
F30 Fire rated
30mins to BS8491
FE180 Fire rated circuit integrity 180mins
F120 Fire rated 120mins (2 hours) to BS8491
E60 Cable rated 60mins as part of a holistic system
E30 Cable rated 30mins as part of a holistic system