Power Cables

Heavy Duty Electrical Wire Suppliers in UAE

Power Cable Specification

 

Verified Manufacturer

Verified Manufacturer (Contact directly for instant quote)

Power Cables Specification

Metal Protections Insulation Sizing Criteria For Conductors
  • Armours
  • Screens
  • XLPE
  • PE, PU
  • PVC, Z1
  • SBR
  • EPR
  • SI, PCP
  • EVA
  • European sizing (mm2)
  • AWG-American Wire Gauge
Jacket Material Cores Type
PVC 2/3/4/5 Insulated
Components Voltage Conductors Type
  • Insulation
  • Auxiliary elements
  • Electric conductor
  • Outer sheath
  • Medium Voltage(1 kV to 36 kV)
  • Low voltage (up to 750 V)
  • High Voltage ( from 36 kV.)
  • Flexible copper
  • Aluminum electrical
  • Bare wire
  • Copper electrical
  • Multi-core
  • Single-core
Color Approvals Install Condition
  • Pink, White, Turquoise
  • Yellow, Orange, Green,
  • Brown, Black, Red
  • Violet, Blue, Gray
  • KEMA KEUR
  • BUREAU VERITAS
  • AENOR
  • CE
  • RoHS
  • Open Air
  • In conduit
  • Buried
  • On tray
Mechanical Performance Environmental Performance Thermal Performance
  •  Minimum bending radius: x5 cable diameter.
  • Impact resistance: AG2 Medium severity.
  • UV Resistant: UNE 211605.
  • Chemical & Oil resistance: Good.
  •  Water resistance: AD8 Submersion.
  • Maximum short-circuit temperature: 250ºC (max. 5 s).
  • Maximum service temperature: 90ºC.

 

Low/ medium/ high voltage Electric Cables at lowest price in Dubai

Voltage Rating Of Electric Cables

Type Voltage
Medium Voltages (MV) > 1 kV and < 33 kV
 Extra High Voltage (EHV) up to 400 kV.
Low Voltages (LV) < 1 kV

 

Armoured & Un-Armoured Industrial Power Cables in Innovative designs and colors

Various Types Of Industrial Power Cables

 

LV Power Cables

LV Power Cables

Heavy Duty Electrical Wires

Heavy Duty Electrical Wire

Multi Core Power Cabless

Multi Core Power Cables

Shielded Power Cabless

Shielded Power Cables

Medium Voltage Power Cables

Medium Voltage Power Cables

Armoured Power Cables

Armoured Power Cables

Un Armoured Power Cables

Un Armoured Power Cables

High Temp Electrical Wire

High Temp Electrical Wire

 

XLPE/ PVC/ Silicone insulated Electrical Cables for Heavy Duty

Heavy Duty Electrical Wire Insulation Material

 

Insulation Description
EPR Ethylene Propylene Rubber
PE Polyethylene
PTFE Poly Tetra Fluoro Ethylene
HEPR Hard Ethylene Propylene Rubber
XLPE Cross Linked Poly Ethylene
PVC Polyvinyl Chloride

 

Designation According to Type of Insulation

Cable type nomenclature
Polyvinyl chloride (PVC) V
Ethylene-propylene elastomer (EPR) D
Cross-linked polyethylene (XLPE) X
Halogen-free thermoplastic polyolefin Z1
Halogen-free thermosetting silicone compound S
Crosslinked polyethylene (XLPE) R
Halogen-free thermosetting elastomer Z

 

LT/ LV Power Cables as per UNE 21123-2 & IEC 60502-1 Standards

Shielded Power Cables Construction

Insulation Type B, A & C (HR) grade
Inner Sheath by extrusion or by PVC tape binding
Conductor
  • Plain bright annealed alluminium
  • copper stranded/solid conductor as per IS: 8130: 1984
Outer Sheath
  • Extruded ST2(HR, FRLS, Halogenfree FRLS)
  • STI type PVC as per IS : 5831: 1984
Armour Gl armour strip/wire as per IS : 3975 : 1974

 

Outer Sheath Designation

Cable type nomenclature
Halogen-free thermoplastic polyolefin Z1
Halogen-free thermosetting elastomer Z
Polyvinyl chloride (PVC) V
Vulcanized chlorinated polymer N

 

High Temp Electrical Wire Termination

  • Cold-shrink
  • Heat-shrink
  • Pre-molded push on

 

LV Power Cables HSN Code

Type HSN Code
Power Cables 85444999

 

Rating Factors Of Electric Wire

  • Max. Conductor temperature. : 71°Celcius
  • Thermal resistivity soil : 151°C CM/W
  • Ground temperature : 31°Celcius
  • Amb. air temperature : 39°Celcius
  • Depth oflaying : 75 centimeter
  • Thermal resistivity of rvc : 640°C CM/W

 

Single Core Power Cables

Nominal Area Of Conductor mm2 Rating Factor
240 1.010
Upto & Including 185 1.007
630 1.000
400 1.004
300 1.008
500 1.000

 

Multi Core Power Cables

Depth Of laying cm Above & 300mm2 Above 25mm2 & 300mm2 Multicore upto 25mm2
90 0.097 0.098 0.099 0.099
75 1 1 1 1
120 0.095 0.096 0.097 0.097
105 0.096 0.097 0.098 0.098
150 0.092 0.094 0.096 0.096
180 or more 0.091 0.093 0.095 0.095

 

Electrical Cables Size chart

CURRENT CONSUMPTION CROSS-SECTION in mm2 (AWG) USED
Under 2.5 mm2 14 Lamps
High air 16 mm2 6 electric power connections.
Very high 25 mm2 4 Central air conditioning
Medium 6 mm2 10 Microwave and blenders
Medium high 10 mm2 8 Refrigerators and dryers.
Medium 4 mm2 12 Lighting
Very low 1.5 mm2 16 Bells, Thermostats, or security systems.