Rubber Cable

Butyl & H07rn-F Cable suppliers in UAE

Rubber Cable Specification

 

Verified Manufacturer

Verified Manufacturer (Contact directly for instant quote)

EPDM Rubber Cable Specification

Voltage Size Standards
1.1 kV to 11 kV
  • 2C, 1C, 4C, 3C, – 0.5 sq mm to 630 sq mm
  • 3.5C— 25 sq mm to 400 sq mm
  • IEC:60092-350
  • IS:14494
  • 15:9968 (P-1 & 2)
  • IEC-60502-1 & 2
  • BS:7919, BS:6195
  • VDE:250
  • NCB:118
  • BS:6007
Inner & Outer Sheathed Construction Range
  • NBR
  • PCP
  • TRS
  • CSP
  • EVA
  • PVC
  • EPR, BUTYYL
  • Tinned Cu
  • Bare Cu
  • VIR
  • SILICON
  • CSP, SBR
  • EVA
  • 2GA, 0GA, 4GA
  • 8GA, 6GA, 10GA
  • 14GA, 12GA, 15GA
  • 18GA, 16GA, 20GA
  • ultra classic strands
Conductor Type Packaging Most Common Rubber Types
  • tin plated copper
  • Stranded 99.99% OFC (oxygen free copper)
  • copper coated al

 

  • Pallet packing
  • Carton packing
  • Wooden /Plastic reels
  • Hypalon
  • Chloroprene [PCP]
  • EPM, EPDM
  • Silicon
  • Natural [NR]
  • Chlorosulphonated polyethylene [CSP]
  • Butyl (IIR)
Insulation Color Conductor Class Conductor Material
  • Red
  • Black
  • Yellow
  • Blue
  • Green
  • Grey
  • Class 1
  • Class2
  • Class 5
  • Class6
Copper
Point to Remember Before Buy Features Application
  • Operating Voltage
  • Bend Radius
  • Color Code
  • Test Voltage
  • Operating Temp
  • Application
  • Resistance to solvents, oil and chemicals.
  • High resistance to cuts , tears & abrasion.
  • Weather resistant and Excellent ozone
  • Outstanding durability.& toughness
  • Electrical instruments
  • Heater cord
  • Electrical blower
  • Portable tools
  • Lighting fixtures
  • Electric iron

 

Rubber Sheathed Cables in various types such as H07rn-F, Silicone, EPDM, Butyl (IIR), EPM, Neoprene, and Nitrile

Types of Flexible Rubber Cable

EPDM Rubber Cable

EPDM Rubber Cable

H07rn-F Cables

H07rn-F Cable

Butyl Rubber Cables

Butyl Rubber Cable

EPR Cables

EPR Cable

TRS Cable

TRS Cable

Neoprene Rubber Cable

Neoprene Rubber Cable

Rubber Armoured Cable

Rubber Armoured Cable

Rubber Insulated Cables

Rubber Insulated Cables

 

Oil resistant Flexible Rubber Cable for tension & high temp environments

H07rn-F Cables Used

Types Application
H07BN-4-F High temperature power supply
H01N2-D / H01N2-E Welding cable
H07RN-8-F temporary use to a depth of 10m
H07RN-F Heavy-duty flexible power supply
0361TQ HOFR Welding cable
H07ZZ-F Halogen free flexible power supply
NSSHOU Heavy-duty flexible power supply with individual core screen with variations including (N)SSHÖU-J, (N)SSHÖU-O, (N)SSHÖU 3E+ST and (N)SSHÖU 3E
NSHOU suitable for permanent submersion available as (N)SHÖU-J and (N)SHÖU-O Heavy-duty flexible power supply 600/1000V
NSGAFÖU Flame and oil resistant cable suitable for high stress environment
NSHXAFÖ Halogen free flexible single conductor cable for circuit-proof applications
NSSCHOU Variation offering an overall Tinned Copper Braid on this robust flexible power supply with Green/Yellow insulation to (N)SSCHÖU-J
NSHTÖU Drum reeling cable
Coil end lead Type 4 Electrical machinery power supply and panel wiring

 

Rubber Insulated Cables for heavy workloads

Working temperature of Butyl Rubber Cable

Material Max. conductor temp for short circuit rating (deg.c) Max. conductor temp for continuous operation (deg.c) Minimum working temperature (deg.c)
NBR PVC 250 90 -30
Polychloroprene 200 70 -40
Ethylene Propylene Rubber (EPR) 250 90 -50
Silicone Rubber 350 150/180 -55
Chloropropylene Ethylene (CPE) 250 90 -30
Chlorosulphonated Polyethylene (CSP) 200 90 -35
Styrene Butadience Rubber 200 60 -55
Manufacturer of Natural Rubber Cables & TRS Cable as per BS 6195/ BS 6500 / BS 6007

Rubber Insulated Cables Construction

General Construction (As Per IS 9968 Part 1)
Sheath General service sheath Type SE2/SE1 of IS 6380-1984
Heavy Duty Sheath Type SE4/SE3 of IS 6380-1984
Seperator Tape applied over the conductor
Conductor Stranded (Class 2), (Class 1) Annealed tinned Solid Copper wires , flexible (Class 5) confirms to requirement of IS 8130-1984
Core Identification Colored proofed tape, Nos. PE tape, Colored insulation, Nos. printing
Insulation Type IE2 of IS 6380-1984
Type IE1 of IS 6380-1984
IE 5 of IS 6380-1984
Fillers synthetic fibers or Natural or elastomer

 

Size chart of EPR Cable

Conductor Nominal Section (mm2) Average Outer Diameter (mm) Conductive Core 200C Conductor Resistance≤(Ω/km)
Max Min Number/Diameter of Core(mm)
25 13.0 10.5 798/0.20 0.758
16 11.5 9.2 513/0.20 1.16
35 14.5 11.5 1121/0.20 0.536
70 19.5 15.0 2214/0.20 0.268
50 17.0 13.5 1596/0.20 0.379
95 22.0 17.0 2997/0.20 0.198

 

Rubber Armoured Cable voltage

Max. Voltage of System(Um/kV) Rated Voltage(U0)/kV
Type C Type A & B
40.5 26 21
12 8.7 6.0
7.2 6.0 3.6
24.0 18.0 12.0
17.5 12.0 8.7
36.0 18.0

 

Color Code of Rubber Sheathed Cables

4 Core: Green/Yellow, Black, Blue, Brown
2 Core: Brown, Blue
1 Core: Black
3 Core: Green/yellow, Brown, Blue
5 Core: Green/Yellow, Black, Blue, Brown, Black

Neoprene Rubber Cable HS Code

Types HS Code
Rubber Cable 85444230

 

Weight Chart of TRS Cable

Stranding (Number of
Strand/Strand Diameter)
Core and Size
mm2
Nominal Overall Diameter
mm
Nominal Overall Diameter
mm
Approx. Weight
kg/km
50×0.25 1x 2.5 6.6 0.9 63
30×0.25 1×1.5 6.0 0.8 49
84×0.30 1×6 8.3 1.0 115
56×0.30 1×4 7.6 1.0 92
126×0.40 1×16 12.0 1.2 260
80×0.40 1×10 10.7 1.2 189
276×0.40 1×35 15.8 1.4 500
196×0.40 1×25 14.1 1.4 369
396×0.40 1×50 18.3 1.6 689
475×0.50 1×95 23.4 1.8 1202
360×0.50 1×70 20.7 1.6 918
608×0.50 1×120 25.6 1.8 1489
925×0.50 1×185 31.0 2.2 2202
2257×0.60 1×630 37.7 3.0 3495
756×0.50 1×150 28.3 2.0 1824
1221×0.50 1×240 34.5 2.4 2847
2013×0.50 1×400 37.7 2.8 3495
1525×0.50 1×300 37.7 2.6 3495
1769×0.60 1×500 37.7 3.0 3495